Our datacenters

Four addresses, not four regions.

Madrid, Amsterdam, Munich, Helsinki. All four inside the EU, on one network. European infrastructure since 2015.

Reply within 24 h

No commitment

A human answers

MAD1Madrid
AMS1Amsterdam
MUN1Munich
HEL1Helsinki
Four datacenters. All live.
DatacenterEdge PoP

Map of Europe showing the four DIVERSITY datacenters: MAD1 in Madrid, Spain, AMS1 in Amsterdam, the Netherlands, MUN1 in Munich, Germany, and HEL1 in Helsinki, Finland. Each site is listed below with its postal town and code, its installed power capacity and its carrier uplinks. Lines join the four sites: the core router at each site is connected to the other three at Layer 2. Smaller dots mark our points of presence, which are edge locations rather than datacenters.

--ms

Your latency to our network

Measured between your browser and our servers as you read this, not taken from a brochure.

How we measure it (opens in a new tab)

Down to the postal code

Each one with its postal town and code, its installed power capacity and its carrier uplinks. We list them west to east, in the map's own order.

4

European datacenters

Madrid, Amsterdam, Munich, Helsinki

44

Points of presence

edge locations in 42 cities, not datacenters

5 MW

Installed power capacity

across the four sites, installed rather than available to sell

18

Carrier uplinks

physical uplinks to tier-1 carriers, added up across the four

MAD1

Madrid

28037 Madrid
Spain

0.5 MW

Power capacity

2

Carrier uplinks

  • Southern Europe core
  • LATAM connectivity hub
  • North Africa gateway

AMS1

Amsterdam

1098 XH Amsterdam
Netherlands

2 MW

Power capacity

6

Carrier uplinks

  • Benelux gateway
  • High-density fiber
  • UK & IE connectivity

MUN1

Munich

81671 München
Germany

2 MW

Power capacity

8

Carrier uplinks

  • DACH market core
  • Finance & industry cluster
  • Central Europe hub

HEL1

Helsinki

00180 Helsinki
Finland

0.5 MW

Power capacity

2

Carrier uplinks

  • Nordic hub
  • Free cooling climate
  • Baltic & Scandinavian reach

Four datacenters. One standard.

Two of the four sites are larger than the other two. Installed capacity describes a building: it sets the most that can be sold there, not what you are sold. Independently audited, carrier-neutral, one operations team, and the seven rows below hold at every one of the four.

CERTIFICATION

Our datacenters are independently audited, not self-assessed. Across the estate that means ISO 27001 for information security, ISO 9001 for process, ISO 14001 for environmental management, and SOC 2 Type 2 where we publish it; our Amsterdam capacity additionally sits in a facility audited against the internet exchange's own colocation standard. Scope and audit dates differ by site and both come with the technical dossier, because a certificate without its scope statement is decoration.

DDOS PROTECTION

Mitigation at the network edge, before traffic reaches your systems. It engages on its own and does not wait for you to open a ticket, which matters because the first ninety seconds are the ones that decide whether an attack is an incident or a graph. Per-customer thresholds are agreed when you sign up rather than discovered during the first event.

CARRIER NEUTRALITY

None of our datacenters is owned by a carrier, so you never buy transit from whoever owns the building, and are never tied to them. We sit directly on the major European internet exchanges, and we peer with AWS, Azure, GCP, Oracle and Cloudflare, so hybrid traffic takes a short, known path instead of whatever a transit provider chooses that day.

FIRE SAFETY

High-sensitivity smoke detection that samples the air continuously rather than waiting for a ceiling sensor to trip, and gaseous suppression that puts a fire out without soaking the racks around it. Rooms are compartmented so an incident stays in the room it started in, and the walls carry a rated fire resistance rather than an assurance.

COLOCATION RACKS

If part of your infrastructure stays on your own hardware, it can live in the same building as your cloud, up to 20 kW per rack at sites that offer it. Same network, same operations team, no hop across the public internet between the two halves of your estate, and one contract rather than two vendors blaming each other.

POWER SUPPLY

Every rack takes independent no-break feeds, and where the facility provides it that is three separate paths rather than the usual two, each behind its own generator. UPS and generators are start-tested on a schedule, not assumed, because the failure mode everyone actually meets is a generator that had not been run since commissioning.

ENERGY AND COOLING

Redundant cooling per room, sized to hold temperature if a unit drops out, with temperature and humidity measured continuously rather than on walk-rounds. Our Amsterdam site runs at a PUE of 1.3 on entirely renewable electricity and pipes half its waste heat into neighbouring homes and university buildings instead of venting it.

The same standard at every site.

Pick a site for latency or for jurisdiction, not for what you get. Every item listed is the floor at all four. Where one facility does more than another, the difference is written into your technical dossier rather than averaged into a number.

The most demanding brands in Europe run on us.

  • Santander
  • BASF
  • Commerzbank
  • AXA
  • Stellantis
  • Finnair
  • Siemens Healthineers
  • Marimekko
  • E.ON
  • Meliá Hotels International
  • Nippon Sanso
  • Siemens Gamesa
  • Ilunion
  • Douglas
  • IFEMA
  • Kemira
  • ISS A/S
  • Iberia
  • Comunidad de Madrid
  • Allianz

A region is a dropdown. An address is a fact.

The four addresses on this page sit in four EU member states, and DIVERSITY is a European company with no parent company, US or otherwise, so there is no entity above us for an order from outside the EU to be served on. Where the racks are and who we are do not change after you sign.

Data in Europe

Workloads and critical data on European infrastructure. No transit through foreign jurisdictions.

GDPR: data protection by design

Built for traceability, compliance, and control. Not a layer added afterward.

European datacenters

Madrid, Munich, Helsinki, Amsterdam. Operated by our own team.

No US parent

No exposure to extraterritorial reach like the CLOUD Act. Jurisdiction is the shield.

Things people ask before signing

Straight answers, no upsell.

Four datacenters is not many. Why not use a provider with dozens of regions?

Four is what we operate, and if your workload needs a region we do not have we will say so rather than sell you the nearest thing. What four buys you is that every one of them is a place we can name, in a country you can check, on one network with one operations team, and the floor is the same at all four. We also run 44 points of presence in 42 cities, and those are a different thing: they are edge locations rather than datacenters, and your servers live in the four.

Where exactly are the four sites?

MAD1 is at 28037 Madrid, in Spain. AMS1 is at 1098 XH Amsterdam, in the Netherlands. MUN1 is at 81671 München, in Germany. HEL1 is at 00180 Helsinki, in Finland. We print the postcode here and not on the product pages, where the metro is as specific as we go.

Are all four live, or is one still being built?

All four are live. None of them is a plan, a phase two or a region we intend to open.

Are the four sites connected to each other?

Yes. The core router at each site is connected to the other three at Layer 2, so the four behave as one network rather than four islands. That is a path rather than a product: it does not replicate your data or fail anything over on its own, and running in two sites is still something you design and buy.

How much power does a site have, and is that what I can use?

Installed capacity is 0.5 MW at MAD1, 2 MW at AMS1, 2 MW at MUN1 and 0.5 MW at HEL1, which is 5 MW across the estate. That is what the sites are built to draw, not what is available to sell, and the two are never the same number in any datacenter. Ask about a site and we will tell you what is available in that hall.

How fast is the network?

Two numbers, and they answer different questions. Capacity is up to 200 Gbit/s to a rack. Traffic is what is actually flowing: around 300 GB/s across the four sites, read off our own status page and rounded down. Watch the units, because they are not the same one: port capacity is quoted in gigabits and that traffic reading is in gigabytes. We publish traffic as one figure rather than four because a per-site split tells you which of our sites is busiest this week, which is our business rather than a property of what you are buying.

Who runs them?

Our own engineers run the network, and one team covers all four sites rather than one per building. What is ours: the network the racks sit on, the transit, the operations and the hands that touch your hardware. Support is free on every product we sell, with a 4-hour target response on support requests. Weekends and out of hours are covered by the advanced support plan, which is paid.

What are the sites certified for, and does it cover all four?

Independently audited rather than self-assessed, and the certifications are listed in full under “Four datacenters. One standard.” above: ISO 27001 for information security, ISO 9001 for process, ISO 14001 for environmental management, SOC 2 Type 2 where we publish it, and, for our Amsterdam capacity, the internet exchange's own colocation standard. The part a compliance reader asks next is the scope. The certificates are held by the facilities, so the scope statement and the audit date differ from site to site, and you get the dossier for the specific site you are buying in rather than a badge.

What happens if a whole site goes down?

Availability is 99.9% by contract with automatic credits if we miss it, and what it measures is the product being up. Running in more than one site is something you design and buy rather than something that happens by itself: nothing replicates between sites unless you have bought it, so a service with nothing bought in a second site is down for as long as its site is. If you want a second site, pick it deliberately and we will help you lay it out.

Can I choose which site my service runs in?

Yes, at order time, whichever product you are buying. Colocation is the one whose lead time depends on the site: rack space is available at short notice in Madrid and Amsterdam, and for Munich and Helsinki we give you a lead time on request, for the space you need.

Can we come and see one?

No, and the reason is the customers already in the building: a data hall is full of other people's hardware, and walking prospects through it is a security problem for them rather than for us. What we can send is photographs, brochures, the facility documentation and the technical dossier for the site you are considering, before you sign anything. If you end up with a rack of your own, access to it is a different question and it is answered in your contract.

Why do you publish the town and the postal code when other providers give a region name?

Because a postal code is checkable and a region name is not. A hyperscaler region names a country or an area, not a building: the provider does not publish which facilities sit inside one, and which ones they are is theirs to change. A postal code puts your hardware in a named municipality under one member state's law, which is the thing an auditor asks for, and a region name does not say which municipality. We still do not name the operator of each building, and that is exactly where the line runs: where it is, yes; who the landlord is, no.

Whose law applies to what we put in them?

The law of the member state the site is in, and EU law above it, including the GDPR. DIVERSITY is European with no US parent and no US-incorporated entity above it, so there is nothing for an order from outside the EU to be served on to reach your data through us. A policy can be revised overnight. A corporate structure cannot be changed quietly.

Pick a site, or ask us which.

Tell us where your users are and what has to stay in the EU.
We will tell you which of the four fits, with the technical dossier for that site before you sign anything.

Reply within 24 h

No commitment

An engineer reviews it